E1439A

Description: E1439A VXI 95 MSa s Digitizer w DSP Memory 70MHz IF input A50+B53

Manufacturer Keysight Technologies
Series VXIbus VMEbus
Part Number E1439A

Need to purchase this item?

tektronix



Keysight E1439A VXIbus Input Module

The Keysight E1439A VXIbus Input Module is designed especially for applications in analysis, high-resolution ATE, and RF signal acquisition. The model has an IF input of 70 MHz, a single channel, and a bandwidth of 36 MHz. The Keysight E1439A has dynamic range without spurious, an expansive signal capture memory, signal conditioning, and center-frequency tunable digital filtering. The E1439A is great for VHF, UHF, and u wave tuners because 70 MHz is a standard IF output for such devices. The IF input provides a 36 MHz alias-protected bandwidth. This can be combined with a high quality tuner, then it will produce wide-band sampled data with an expansive dynamic range. This is perfect for use with spectrum analysis and digital radios.

The E1439A has an 18 Mbyte FIFO memory with 144 Mb, 288 MB, and 1.2 GB options available. This model also has a fast data transfer rate of as high as 190 MB/sec, with multiple ways to transport information. One way is the VXI-bus, which can transport information at 2-4 MB/sec. The VXI local bus, however, can transport information at rates as high as 50 MB/sec.

The Keysight E1439A has multiple ways of being triggered. Immediate trigger mode starts instantly. External trigger mode is best when sampling has to begin at the same time as an external event. The level mode triggers on the same level as the input signal. A software trigger mode is also available. Pre-trigger and post-trigger postponements are a regular occurrence.

ModelE1439A
ManufacturerKeysight
SeriesHP Agilent VXIbus Input Module
TypeVXIbus Input Module
IF input70 MHz
Channels1
Bandwidth36 MHz
Memory18 Mbyte FIFO with 144 or 288 MB, or 1.2 GB options
StatusOne Year
E1439A ManualUser Manual and Maintenance Manual Available for Download
ApplicationIndustrial

Keysight E1439A VXIbus Input Module- FAQ:

Question:

What is the baseband input of the Keysight E1439A?

Answer:

The baseband input is -21 dBm.

 

Question:

What is the raw resolution of the E1439A?

Answer:

The raw resolution is 12 bits.

 

Question:

Does the E1439A have any options available?

Answer:

Yes, Option 144 expands the memory to 144 MB and Option 288 expands it to 288 MB FIFO memory.

 

Question:

What is the signal-to-noise ratio for the E1439A?

Answer:

The signal-to-noise ratio is greater than 60 dB.

 

Question:

What is the standard operating temperature for the E1439A?

Answer:

The operating temperature is 0 to 55 degrees C.