M9361A

Description: Keysight M9361A PXI Downconverter 2.7 GHz to 26.5 GHz

Manufacturer Keysight Technologies
Series PXI
Part Number M9361A

Need to purchase this item?

tektronix



Keysight M9361A PXI Downconverter

The Keysight M9361A PXI Downconverter from Agilent/Keysight Technologies is enhanced for use with the Agilent PXI Digitizers in aviation and defense applications, such as radar and wideband signal capture, and wireless communication applications. This model from Agilent measures the signal ways from the LO IN and RF IN connectors to the SI OUT connector.

The M9361A has a SMA female connector that inputs a signal (2.75 GHz to 26.5 GHz) for downconversion. The working extent is - 30 dBm to - 160 dBm. Harm happens over 10 dBm. This modular PXI product also has a male SMB connector that is utilized to change to an outside IF flag (100 kHz to 500 MHz) legitimately to the IF OUT and to dodge the downconversion procedure of the M9361A. This IF signal is accessible straightforwardly from the IF OUT connector. All SMA connectors are torqued to 8 Lb-In (0.904 Nm).

This 1-slot PXI Downconverter has an LED that demonstrates the general status of the M9361A and is an outline of the accompanying LEDs, which spread power supplies and other equipment tasks. The M9361A has broad coordinated testing (BIT) and can distinguish explicit issues by looking at the status pointer on the front board. The activity checks of the Keysight PXI M9361A Downconverter measure the signal from the IN and RF IN connectors to the IF OUT connector.

M9361A paths are accurately set from the SFPs so that once the signal generator is set to the correct power/frequency, all links are legitimately associated.

ModelM9361A
ManufacturerKeysight Agilent HP
TypePX Downconverter
Frequency Range2.75 GHz to 26.5 GHz
Slot Requirements1
Operating Range-146 dBm to -30 dBm, (nominal) (< 9.5 GHz, -160 dBm)
Bandwidth (3 dB)250 MHz, min
Size3U
Life Cycle StatusDiscontinued
StatusObsolete
M9361A ManualUser Manual and Maintenance Manual Available for Download
ApplicationIndustrial

Keysight M9361A Frequently Asked Questions

 

Question: What are the standard compliant drivers for the M9361A?

 

Answer: The standard compliant drivers for the M9361A are MATLAB, IVI-COM, LabVIEW, and IVI-C.

 

Question: Can the M9361A be “hot-swapped?”

 

Answer: No, PXI hardware such as the M9361A does not support “hot-swap.” Make sure to power off the chassis prior to installing or removing a module.

 

Question: Which accessories can be used with the Keysight M9361A?

 

Answer: The Keysight M9361A can be used with the Y1182A PXI connector block and the Y1189A PXI connector cable.