Description: 60502B 300 Watt dc Electronic Load Module Agilent / Keysight / HP
Manufacturer | Keysight Technologies |
---|---|
Series | 6050 Series |
Part Number | 60502B |
Need to purchase this item?
Agilent 60502B Electronic Load Module
The 60502B is a 300 watts electronic load module. This module fits in 6050A or 6051A Multiple-Input electronic Load Mainframes to provide variable load functionality.
Each module can operate in three modes.
a. Constant current (CC) mode
b. Constant voltage mode (CV)
c. Constant resistance mode (CR).
Specifications:
Current | 0 to 60 A |
Voltage | 3 to 60 V (min dc operation from 0 to 2 Volts for 0 to 60 A) |
Power | 300 Watts at 40 °C derated to 225 Watts at 55 °C |
Constant Current Mode:
Ranges | 0 to 6 A, and 0 to 60 A |
Accuracy | (After 30 seconds delay): ±0.1% ±75 mA (both ranges) |
Resolution | 1.6 mA (6 A range); 16 mA (60 A range); |
Regulation | 10 mA (both ranges) |
Temperature Coefficient | 100 ppm/ °C ±5 mA/ °C (both ranges) |
Constant Resistance Mode:
Ranges | 0.033 to 1 Ω; 1 Ω to 1 kΩ; 1 kΩ to 10 kΩ; |
Accuracy | ±0.8% ±8 mΩ with ≥ 6 A at input (1 Ω range); ±0.3% ±8 mS with ≥ 6 V at input (1 kΩ & 10 kΩ ranges); |
Resolution | 0.27 mΩ (2 Ω range); 0.27 mS (1 kΩ range); 0.027 mS (10 kΩ range); |
Regulation | 10 mV with remote sensing (1 Ω range); 10 mA (1 kΩ & 10 kΩ ranges); |
Temperature Coefficient | 800 ppm/ °C ±0.4 mΩ/ °C (1 Ω range); 300 ppm/ °C ±0.6 mS/ °C (1 kΩ & 10 kΩ ranges); |
Constant Voltage Mode:
Ranges | 0 to 60 V |
Accuracy | ±0.1% ±50 mV |
Resolution | 16 mV |
Regulation | 5 mV (remote sensing); 40 mV (Local sensing) |
Temperature Coefficient | 100 ppm/ °C ±5 mV/ °C |